{"id":2925,"date":"2020-12-29T12:21:35","date_gmt":"2020-12-29T11:21:35","guid":{"rendered":"https:\/\/cirrus-centar.hr\/solutions\/gas-detection\/smjestaj-senzora\/"},"modified":"2021-09-27T12:31:41","modified_gmt":"2021-09-27T10:31:41","slug":"sensor-placement","status":"publish","type":"page","link":"https:\/\/cirrus-centar.hr\/en\/solutions\/gas-detection\/sensor-placement\/","title":{"rendered":"Sensor placement"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<span class=\"NormalTextRun SCXW65072379 BCX0\">The two most common questions asked when choosing a gas detection system are how many detectors will be needed and where they will need to be placed. Particularly, in the case of gas detection systems, the location and quantity of detectors in different\u00a0<\/span><span class=\"NormalTextRun SCXW65072379 BCX0\">applications<\/span><span class=\"NormalTextRun SCXW65072379 BCX0\"> is not precisely defined.<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;cta-rjesenja&#8221;][vc_column width=&#8221;1\/6&#8243;][\/vc_column][vc_column width=&#8221;5\/6&#8243; offset=&#8221;vc_hidden-sm vc_hidden-xs&#8221;][vc_cta h2=&#8221;The position of the sensor is extremely important and depends on many factors.&#8221; add_button=&#8221;right&#8221; btn_title=&#8221;Contact us&#8221; btn_style=&#8221;modern&#8221; btn_size=&#8221;xl&#8221; btn_skin=&#8221;primary&#8221; btn_link=&#8221;url:https%3A%2F%2Fcirrus-centar.hr%2Fen%2Fcontact%2F|title:Contact&#8221; css=&#8221;.vc_custom_1632738696708{margin-bottom: -150px !important;}&#8221;]<span class=\"TextRun BCX0 SCXW19407686\" lang=\"EN\" xml:lang=\"EN\" data-contrast=\"none\"><span class=\"NormalTextRun BCX0 SCXW19407686\" data-ccp-charstyle=\"y2iqfc\">Do you have special requirements? We are here to advise you<\/span><\/span><span class=\"EOP BCX0 SCXW19407686\" data-ccp-props=\"{&quot;201341983&quot;:2,&quot;335559739&quot;:0,&quot;335559740&quot;:240,&quot;469777462&quot;:[916,1832,2748,3664,4580,5496,6412,7328,8244,9160,10076,10992,11908,12824,13740,14656],&quot;469777927&quot;:[0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0],&quot;469777928&quot;:[1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1]}\">\u00a0<\/span>[\/vc_cta][\/vc_column][\/vc_row][vc_row el_class=&#8221;porto-schedule-timeline-item&#8221;][vc_column]<div class=\"wpb_custom_aa84c36a6a947f6099708744f0f74b68\"><div class=\"timeline-circle background-color-primary border-transparent no-box-shadow text-color-light center m-b-lg  small \"><div class=\"circle-dotted\"><div class=\"circle-center\"><span class=\"step-title text-color-light font-weight-bold m-b-none\"><\/span><span class=\"step-subtitle text-color-light\">Location and quantity of detectors<\/span><\/div><\/div><\/div><div class=\"timeline-balloon p-b-lg m-b-sm \"><div class=\"balloon-cell balloon-time\"><span class=\"time-text step-item-subtitle\"><\/span><div class=\"time-dot background-color-light\"><\/div><\/div><div class=\"balloon-cell\"><div class=\"balloon-content  balloon-shadow background-color-light\"><span class=\"balloon-arrow\"><\/span><div class=\"balloon-description\"><div class=\"step-item-desc\">Various standards are available to consider and address this problem, for example EN 60079-29-2 relating to the selection, installation, use and maintenance of devices for the detection and measurement of flammable gases and oxygen.<\/div><\/div><\/div><\/div><\/div><div class=\"timeline-balloon p-b-lg m-b-sm \"><div class=\"balloon-cell balloon-time\"><span class=\"time-text step-item-subtitle\"><\/span><div class=\"time-dot background-color-light\"><\/div><\/div><div class=\"balloon-cell\"><div class=\"balloon-content  balloon-shadow background-color-light\"><span class=\"balloon-arrow\"><\/span><div class=\"balloon-description\"><div class=\"step-item-desc\">Although these references are useful, they can be generic and too detailed or application-specific, which is why references are often irrelevant to most applications. The location of the sensor should be determined by experts who have knowledge in the field of gas dispersion combined with the knowledge of process engineers and personnel working in occupational safety.<\/div><\/div><\/div><\/div><\/div><div class=\"timeline-balloon p-b-lg m-b-sm \"><div class=\"balloon-cell balloon-time\"><span class=\"time-text step-item-subtitle\"><\/span><div class=\"time-dot background-color-light\"><\/div><\/div><div class=\"balloon-cell\"><div class=\"balloon-content  balloon-shadow background-color-light\"><span class=\"balloon-arrow\"><\/span><div class=\"balloon-description\"><div class=\"step-item-desc\"><span class=\"TextRun BCX0 SCXW23250550\" lang=\"EN\" xml:lang=\"EN\" data-contrast=\"none\"><span class=\"NormalTextRun BCX0 SCXW23250550\" data-ccp-charstyle=\"y2iqfc\" data-ccp-charstyle-defn=\"{&quot;ObjectId&quot;:&quot;35914a2a-60a9-4e17-8f58-a7be8f28dd12|16&quot;,&quot;ClassId&quot;:1073872969,&quot;Properties&quot;:&#091;134233614,&quot;true&quot;,201340122,&quot;1&quot;,469775450,&quot;y2iqfc&quot;,469778129,&quot;y2iqfc&quot;,469778324,&quot;Default Paragraph Font&quot;&#093;}\">Detectors must be installed\u00a0<\/span><span class=\"NormalTextRun BCX0 SCXW23250550\" data-ccp-charstyle=\"y2iqfc\">on place\u00a0<\/span><span class=\"NormalTextRun BCX0 SCXW23250550\" data-ccp-charstyle=\"y2iqfc\">where gas is expected to be present. The places that require the most attention are near gas boilers, compressors, pressure vessels, pipelines and cylinders. Valves, gauges, flanges, pipe elbows, etc. are also the places where gas leaks are most likely to occur.<\/span><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"timeline-balloon p-b-lg m-b-sm \"><div class=\"balloon-cell balloon-time\"><span class=\"time-text step-item-subtitle\"><\/span><div class=\"time-dot background-color-light\"><\/div><\/div><div class=\"balloon-cell\"><div class=\"balloon-content  balloon-shadow background-color-light\"><span class=\"balloon-arrow\"><\/span><div class=\"balloon-description\"><h5 class=\"step-item-title text-color-dark font-weight-bold p-t-xs\">There are several facts to consider when determining the location of a detector:<\/h5><div class=\"step-item-desc\">\n<ul>\n<li>For the detection of gases lighter than air (e.g., methane, ammonia) the detectors must be placed at a higher altitude<\/li>\n<li>For the detection of gases heavier than air (e.g. butane, sulfur dioxide), the detectors must be placed at a lower altitude<\/li>\n<li>Consider how the gas will behave at lower and higher airflow. If necessary, detectors can be installed in ventilation ducts<\/li>\n<li>Consider the influence of weather conditions on detector operation. For detectors installed outdoors, the installation of weather protection is recommended<\/li>\n<li>Use sunshade if the detector is installed in direct sunlight or in warm climates<\/li>\n<li>Consider procedural conditions. For example, butane is heavier than air, but if it leaks at high temperature and pressure, it can rise to higher altitudes.<\/li>\n<li>Consider easy access to the detector for easier maintenance<\/li>\n<li>When installing an IR detector in a beam, it is important to ensure that there is nothing that could block the IR beam<\/li>\n<\/ul>\n<p><\/div><\/div><\/div><\/div><\/div><\/div>[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]The two most common questions asked when choosing a gas detection system are how many detectors will be needed and where they will need to be placed. Particularly, in the case of gas detection systems, the location and quantity of detectors in different\u00a0applications is not precisely defined.[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;cta-rjesenja&#8221;][vc_column width=&#8221;1\/6&#8243;][\/vc_column][vc_column width=&#8221;5\/6&#8243; offset=&#8221;vc_hidden-sm vc_hidden-xs&#8221;][vc_cta h2=&#8221;The position of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2908,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/pages\/2925"}],"collection":[{"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/comments?post=2925"}],"version-history":[{"count":0,"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/pages\/2925\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/pages\/2908"}],"wp:attachment":[{"href":"https:\/\/cirrus-centar.hr\/en\/wp-json\/wp\/v2\/media?parent=2925"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}