MicroRAE

MicroRAE is a wireless multi-gas detector that monitors up to four gases simultaneously, including H2S, CO, O2 and LEL. With included multiple MicroRAE wireless connectivity options for easy data transfer to PC and processing.

Read More About Gas

Carbon Monoxide

Carbon Monoxide

The silent killer, one of the most dangerous and insidious gases, the product of incomplete combustion of fossil fuels. The gas is tasteless and odorless, transparent, unrecognizable, and accumulates in the blood (hemoglobin) with an affinity 240 times higher than oxygen! Concentrations of 300 parts per million in the air (ppm) are already deadly to an adult.

Even the lowest concentrations accumulate in the blood, so the Short Time Exposure Limit (STEL) or maximum allowed accumulated exposure concentration is only 20 ppm, and the daily 8-hour maximum allowed average accumulated exposure (TWA - Time Weighted Average) is 100 ppm. There is a great danger in homes that use fossil fuels, and it is part of the process in ironworks, power plants, petrochemicals, etc.

The standard settings for the lower and upper alarm thresholds are 20 ppm and 100 ppm, and gas also accumulates in the body, so the standard STEL Limit is also 100 ppm, with a TWA limit of 20 ppm.

Hydrogen Sulfide

Hydrogen Sulfide

Hydrogen sulfide is a poisonous, colorless and corrosive gas that occurs as a by-product of the decomposition of organic matter without the presence of oxygen (wetlands, sewage) by anaerobic microorganisms. It also occurs in volcanic gases, geothermal springs and along deposits of natural gas (up to 30%) and crude oil. It also occurs in the human body as a product of metabolism, and even in the breath in some disorders. The largest industrial emitters of hydrogen sulfide are oil refineries (oil hydrodesulfurization process - HDS, Claus process), gas plants, petrochemicals, pharmaceutical industry, coke ovens, paper mills and sewage and drainage systems. The positive side of this very poisonous gas is that in very small concentrations (50 ppb) it can be felt as an unpleasant smell of rotten eggs so this is the first warning. However, with a rapid increase in concentration (which is most often the case), the mucous membrane and the sense of smell are paralyzed and the unpleasant odor completely disappears while the toxicity increases. At concentrations higher than 50 ppm, visual impairment occurs.

The standard settings for the lower and upper alarm thresholds are 5 ppm and 10 ppm, and gas also accumulates in the body, so the standard STEL Limit is 10 ppm, and the TWA limit is 5 ppm.

Flammable group of gases (Hydrocarbons)

Hydrocarbons

They occur in practically every segment of life. The most famous representative is natural gas (methane, CH4), and the combinations of carbon and hydrogen molecules are practically unlimited. We use them as energy sources in all endothermic processes and in almost all industries (chemical, petroleum, pharmaceutical, petrochemical). The biggest problem is their flammability and explosiveness, and for the most part, toxicity. They are one of the biggest risks in all industries. Flammability directly depends on their concentration in the air mixture and ranges between LEL - Lower Explosive Limit and UEL - Upper Explosive Limit. At concentrations of 4.4% to 17% by volume of methane in the air, the spark causes an explosion, so 4.4% v / v CH4 = 100% LEL.

The standard limits of alarm settings within the EU are Low = 10% LEL, High = 20% LEL

Oxygen

Oxygen

Gas which is essential for life, in a concentration of 20.9% v / v makes our planet unique. It supports burning and is part of almost all natural and human created processes that take place on Earth. Concentrations below 16.0% v / v cause drowsiness and confusion, and below 6% v / v death. It is also dangerous in high concentrations because it increases the flammability of the material. Concentrations above 24.0% v / v may cause spontaneous combustion of clothing.

The standard limits of alarm settings within the EU are Low = 19.5% v / v, High = 23.5% v / v

Clear
  • Available in several wireless options: Mesh / Wi-Fi / NB – IoT
  • Real-time gas concentration, location and alarm readings
  • Bluetooth connection to a smartphone for communication and device configuration
  • Compact and lightweight
  • Short time to perform bump test and calibration
  • LEL sensor option with filter to inhibit sensor poisoning
  • Dimensions: 11.7 x 7.6 x 2.4 cm
  • Weight: 206 g
  • Operating temperature: -20 to +60 ° C
  • Self-test of sensors, battery and visual / audible alarms when turned on
  • IP 65/66 degree of protection
  • ATEX Zone 1
  • Oil and gas industry
  • Wastewater treatment
  • Telecommunications
  • Construction
  • Chemical and petrochemical industry
  • Firefighting

ACCESSORIES / OPTIONS:

  • Calibration adapter
  • Professional suitcase for endangered space, includes:
    • Manual aspiration pump
    • Cause probe with replacement filter
    • Tygon hose 2 m long, replacement filters
  • Options for safe wearing (belt, straps, leather protection)
  • Sample probe with hydro particle filter
  • Charger options (5 detectors simultaneously, standard / cradle, car charger)